Rohde & Schwarz uwave Accesories |
 |
Adaptors Coax- Coax
|
 |
Adaptors Coax - Waveguide
|
 |
Amplifiers
|
 |
Antennas
|
 |
Fixed Attenuators
|
 |
Step Attenuators
|
 |
Bias Networks
|
 |
Cables
|
 |
Calibration Kits
|
 |
Combiners/Dividers/Power Splitters
|
 |
Connectors
|
 |
Couplers
|
 |
DC Blocks
|
 |
Detectors
|
 |
Bridges
|
 |
Filters
|
 |
Matching Pads
|
 |
Mixers/ (de) Modulators
|
 |
Multipliers
|
|
Noise Measurement
|
 |
Phase Shifters
|
 |
Probes
|
 |
RF Switches, Mechanical, Solid State
|
 |
Sliding Loads
|
 |
Terminations
|
 |
Tools & Torque Wrenches
|
Hameg Microwave Accessories |
|
|
 |
HZ20 Adaptor Plug
for connection from BNC socket to 4 mm banana plugs
|
 |
HZ21 Adaptor Plug
for connection from N socket to BNC plug
|
 |
HZ22 Feed-Through Terminal 50 Ohm
1 GHz, 1 Watt
|
 |
HZ24 Attenuators 50 Ohm
One set of 50 ΩO attenuators with 3/6/10/20 dB
attenuation (1 GHz, 1 Watt) and 1x HZ22
|
 |
HZ26 BNC-T-Adaptor
BNC T-adapter, UG274, 50 Ohm
|
|
|
 |
HZ10 Silicone Test Lead
Silicone sheathed test lead with stackable banana plugs,
set of 5 x 1m.
|
 |
HZ15 PVC Test Lead
PVC sheathed test lead with test probes and sheathed
banana plugs.
|
 |
HZ16 Test Cable With Micro Clamps
Silicone-sheathed test lead with BNC plug to miniature
clamp probe
|
 |
HZ17 4-Wire Test Lead
4-wire test lead with test probe and 5-pole DIN
connector for HM8014 and HM8018
|
 |
HZ18 Kelvin Test Lead
Kelvin test lead with gold-plated Kelvin contacts,
5-pole DIN connector and shielding mass on alligator
clip, for HM8014 and HM8018
|
 |
HZ19 Test Tweezers
Kelvin test lead with SMD test tweezers, 5-pole DIN
connector for HM8018
|
 |
HZ31 Test Cable 50Ohm
Test cable, 50 Ohm BNC to BNC angle connector. Length
1m.
|
 |
HZ32 Test Cable
Test cable, BNC to 4 mm banana plug . Length 1m
|
 |
HZ33/HZ34 Test Cable 50 Ohm
Test cable, 50 Ohm, BNC to BNC straight plug. HZ33 -
0.5m, HZ34 - 1m
|
 |
HZ33S/HZ34S Test Cable 50 Ohm
Test cable, 50 Ohm, BNC to BNC socket, insulated . HZ33S
- 0.5m.HZ34S - 1m.
|
|
|
 |
HZ200 1:1/10:1
Attenuation ratio: 10:1 Bandwidth: 250 MHz Rise time: <
2.4 ns Input impedance: 10 M Ohm II 12 pF Max. voltage:
400 V (DC + peak AC).
|
 |
HZ51 10:1
Attenuation ratio: 10:1 Bandwidth: 150 MHz Rise time:
<2,4 ns Input impedance: 10 M Ohm II 12pF. Max. voltage:
600 V (DC + Peak AC)
|
 |
HZ52 10:1
Bandwidth: 250 MHz Rise time: <1,4 ns Input impedance:
10 MΩO II 10pF Max. voltage: 600 V (DC + Peak AC)
|
 |
HZ53 100:1
Bandwidth: 100 MHz Rise time: < 3,5 ns Input impedance:
100 MΩ? II 4,5 pF Max. voltage: 1200 V (DC + peak AC)
|
 |
HZ154 1:1 / 10:1
Attenuation ratio: 1:1 Alt. Attenuation ratio: 10:1
Bandwidth: 10/150 MHz Rise time: <35/3,5 ns Input
impedance: 1/10 M Ohm II 82/12pF.Max. voltage: (10:1)
600 V (DC + Peak AC)
|
 |
HZ100 Differential Probe 20:1 / 200:1
Differential input voltage (DC + peak AC), max.: ±700V
Max. input voltage per input: ± 700V Attenuation ratio:
20:1 Alt. attenuation ratio: 200:1 Bandwidth: 30/40 MHz.
|
 |
HZ109 Differential Probe 1:1 / 10:1
Differential input voltage (DC + peak AC), max.: ±35V
Max. input voltage per input: ± 35V Attenuation ratio:
1:1 Alt. attenuation ratio: 10:1 Bandwidth: 20/30 MHz
|
 |
HZ115 Differential Probe 100:1 / 1000:1
Differential input voltage (DC + peak AC), max.: ±1500V
Max. input voltage per input: ±1500V Attenuation ratio:
100:1 Alt. attenuation ratio: 1000:1 Bandwidth: 20/30
MHz
|
|
|
 |
HZ70 Opto-Interface
The Opto-Interface HZ70 is an optical fiber transmission
line. The interface protocol corresponds to that of the
RS-232 interface. It is used in cases where the test
configuration requires galvanic separation or
transmission must be free of interference.
|
 |
HZ72L IEEE-488 Interface Cable
IEEE-488 bus interface cable. double-shielded, 90°
angle, stackable Length: 1.5 m – HZ72L
|
 |
HZ73 IEEE-488 Interface Cable
Double shielded, 90° angle on one side, stackable
Length: 2.0 m
|
|
|
 |
HZ56 Test Unit
This AC/DC Test Unit is used to measure currents from 1
mA to 30 A over a broad frequency range. The measurement
principle is based on a sensitive echo sensor that
registers the magnetic field generated by the current
flow.
|
 |
HZ812 PT100 Temperature Probe
The HZ812 and HZ887 Temperature Probes are immersion
sensors with a platinum test resistance of PT 100.
They ensure excellent precision over a broad
temperature range. The probes are of robust
construction, waterproof and also suitable for use
in air or dusty environments. -50°C to +400°C
|
 |
HZ887 PT100 Temperature Probe
The probe is connected to the measuring instrument with
a 4-wire connector via 4 mm banana plugs. The length of
the connector cable is 1.2 m. Temp range:-50°C to +400°C
|
|
|
 |
HZ809 Test Adaptor For Modular System 8000
Test adapter for the testing and repair of insert
modules for Modular System 8000 outside the basic
mainframe unit HM8001-2. The module connection terminals
in the basic unit HM8001-2 are pulled out 1 to 1. The
insert modules can then be operated outside the unit
while the housing is open.
|
 |
HZ815 Test Adaptor For Modular System 8000
Adapter for simplified measurement of power consumption,
line voltage and current consumption of mains operated
consumer (3-wire grounding-type plug or European
standard plug) using the HM8015 and HM8115-2 power
Meters.
|
|
|
 |
HZ520 Plug-In Antenna
Plug-in antenna for HF reception. BNC connection
|
 |
HZ530 Near Field Probe Set
The HZ530 Probe Set consists of 3 active broadband
probes for EMC diagnosis. The probes are designed for
connection to a HAMEG spectrum analyzer and have an
impedance of 50 Ohm at the coaxial output.
|
 |
HZ540 Near Field Probe Set
The HAMEG HZ540 and HZ550 are active close field probe
sets designed for use as a diagnostic aid in the
solution of emissions problems. The sets consist of
three or five different handheld probes resp.. They
feature different sensitivities and reception
characteristics.
|
 |
HZ541 VSWR Test Unit
This unit is used to measure the voltage standing wave
ratio (VSWR) and the reflection coefficient of a device
under test with an impedance of 50 Ohm. Typical test
objects include attenuators, terminations, frequency
switches, amplifiers, cables and mixers. The measurement
range is specified from 150 kHz to 1 GHz.
|
 |
HZ560 Transient Limiter
The HZ560 Transient Limit protects the input circuits of
spectrum analysers and test receivers. The input of the
Transient Limiter is connected via BNC cable to the
signal source. The output can be connected directly to
the spectrum analyzer.
|
 |
HZ575 Converter
HZ575 is a 75 Ohm to 50 Ohm converter enabling
measurement in 75 Ohm systems in connection with 50 Ohm
input impedance spectrum analysers. The 75 Ohm input is
a 75 Ohm BNC socket which is AC coupled internally. The
output is a 50 Ohm N male connector which is DC coupled.
HZ575 can also be used for reverse operation converting
50 Ohm to 75 Ohm.
|
|
|
 |
HZ42 19” Rackmount Kit 2U
For mounting HAMEG instruments with a case height of 75
mm (e.g. Series 8100 System Instruments)
|
 |
HZ43 19” Rackmount Kit 3U
For mounting HAMEG instruments with a case height of 125
mm (excepting HM1000, HM1500, HM1008, HM1508)
|
 |
HZ45 19” Rackmount Kit 4U
For mounting HAMEG instruments with a case height of 125
mm (for HM1000, HM1500, HM1008, HM1508).
|
Huber+Suhner Microwave Accesories |
 |
RF Connectors
HUBER+SUHNER are a leading supplier of RF connectors for
signal (voice / data) transmissions with many years of
experience engineering and producing coaxial connectors.
|
 |
RF Cables
HUBER+SUHNER develops and manufactures coaxial cables
for virtually any application or international standard.
Their modern cable production incorporates ongoing
analysis during production, constant quality control and
the latest finishing methods.
|
 |
RF Cable Assemblies
HUBER+SUHNER offer you ready-to-use, high performance
assemblies from one single source, produced by
state-of-the-art methods from carefully selected cables
and connectors
|
 |
Wireless Datalinks
SENCITY®LINK operates as a point-to-point wireless data
link with a data rate of 100 Mbps over a distance of up
to 800 m (2600 ft). Measuring only 16 × 16 cm (6.3" ×
6.3"), its compact size is attained by extensively
integrating the active and passive components. The
product version SL60-100-57/64-38-E-O operate
|
 |
Antennas
HUBER+SUHNER designs and manufactures an extensive
product portfolio of directional and omni directional
antennas for various wireless applications for the
communication, transportation and industrial markets.
|
 |
RF Lighting Protectors
HUBER+SUHNER's high quality Lightning Protection
components are available for applications in the
frequency range from DC to 18 GHz. Many of our patented
products have set world-wide industry standards.
Our product portfolio includes protectors for almost
every RF application
|
 |
RF Power Splitters
HUBER+SUHNER Power Splitters are low loss reactive
splitters for the distribution of RF signals to radio
transceiver antenna systems including radiating cables.
The RF power is evenly split to all outputs with
excellent amplitude and phase balance.
|
 |
RF Power Switch
The pioneering new RF Power Switch is HUBER+SUHNER’s
ideal response to this challenge. This radio-frequency
switch comprises a whole new product family used in base
stations. The simple plug and play concept makes it easy
to switch between two channels
|
 |
RF Components
Attenuators, terminations ,DC blocks, impedance matching