RF Test Equipment, Spectrum Analyser, Signal Generator, Power Meter, EMC Test Equipment, TV Test Equipment, Oscilloscopes, Power Analyser, Kyoritsu, Hameg, Rohde & Schwarz, Yokogawa, Calibration, Environmental Testers, Multimeters, Insulation Testers, Thermal imaging, Network Analysers, Protocol Testers, Broadcast Test Equipment, MPEG Analysers, Promax, Thickness Testers, Concrete Testers, Radio Testers, Comms Analysers, Modulators, Demodulators, Fluke, Test Equipment, Test & measurement in Queensland, LCR Meters, Handheld Test Equipment, Power Supplies, Data Aquisition, Data Loggers, Meggers, PAT Testers, Portable Appliance Testers, Clamp meters, Function Generators, Calibrators, Temperature Measurement, Vibration Meters, Surface Roughness Testers, Recorders, Amprobe, Home About Us Search Links Products Suppliers Contact Us
Search for Product

Temperature Calibration

Micro-Baths

Model Range Accuracy Description/Features Email
6102
Micro-Bath
35 °C to 200 °C
95 °F to 392 °F
±0.25 °C World’s smallest calibration bath.
Stability to ±0.02 °C.
Stirred 2.5-inch-diameter tank.
Enquiry
7102
Micro-Bath
–5 °C to 125 °C
23 °F to 257 °F
±0.25 °C Portable bath to –5 °C.
No refrigeration—solid-state cooling.
 Stability to ±0.015 °C.
Enquiry
7103
Micro-Bath
–30 °C to 125 °C
–22 °F to 257 °F
±0.25 °C Ultracold Micro-Bath reaches –30 °C.
 No refrigeration or external cooling needed.
Stability to ±0.03 °C.
Enquiry

Handheld Dry-wells

Model Range Accuracy Description/Features Email
9100S
Handheld
Dry-Well
35 °C to 375 °C
95 °F to 707 °F
±0.25 °C at 100 °C
±0.5 °C at 375 °C
World’s smallest dry-well.
Fixed block with 4-inch well depth.
Four hole patterns available.
Enquiry
9102S
Handheld
Dry-Well
–10 °C to 122 °C
14 °F to 252 °F
±0.25 °C Handheld unit cools to –10 °C.
Two 0.5-inch-diameter, removable sleeves.
Enquiry

Field Dry-wells

Model Range Accuracy Description/Features Email
9009
Dual-Block Calibrator
–15 °C to 350 °C
5 °F to 662 °F
Cold block: ±0.2 °C
Hot block: ±0.6 °C
Dual-block industrial dry-well.
Each block has two wells with removable sleeves. Water- and air-tight enclosure.
Enquiry
9103 Field
Dry-Well
–25 °C to 140 °C
–13 °F to 284 °F
±0.25 °C Small, lightweight field calibrator reaches –25 °C.  Stability to ±0.02 °C.
Calibrates up to six probes at once.
Enquiry
9140 Field
Dry-Well
35 °C to 350 °C
95 °F to 662 °F
±0.5 °C Portable field calibrator. Choose from four multi-hole, removable inserts. Enquiry
9141 Field
Dry-Well
50 °C to 650 °C
122 °F to 1202 °F
±0.5 °C to 400 °C
±1 °C to 650 °C
High-temp field calibrator. Interface-it
software and RS-232 included. Extremely small and fast for temperature range.
Enquiry
9142 Field
Dry-Well
–25 °C to 150 °C
–13 °F to 302 °F
±0.2 °C Field Metrology Well.
Built-in readout for PRT, RTD,
thermocouple, 4-20mA current.
Enquiry
9143 Field
Dry-Well
33 °C to 350 °C
91 °F to 662 °F
±0.2 °C Field Metrology Well.
Built-in readout for PRT, RTD,
thermocouple, 4-20mA current.
Enquiry
9144 Field
Dry-Well
50 °C to 650 °C
122 °F to 1202 °F
±0.35 °C at 50 °C
±0.35 °C at 420 °C
±0.5 °C at 650 °C
Field Metrology Well.
Built-in two-channel readout for PRT, RTD,
thermocouple, 4-20mA current.
Enquiry
3125 Surface Calibrator 35 °C to 400 °C
95 °F to 752 °F
±0.5 °C to 200 °C
±1.0 °C to 400 °C
Calibrates surface sensors.
Plate stability of ±0.3 °C.
Enquiry

Infrared Calibrators

Model Range Accuracy Description/Features Email
9132 50 °C to 500 °C
122 °F to 932 °F
±0.5 °C at 100 °C
±0.8 °C at 500 °C
Certifies most handheld pyrometers.
Short heating and cooling times.
Enquiry
9133 –30 °C to 150 °C
–22 °F to 302 °F
±0.4 °C Calibrates at cold temperatures.
Gets to desired temperature quickly.
Enquiry
9135
3-Pt. IR
Calibrator
50 °C, 100 °C, 150 °C
122 °F, 212 °F, 302 °F
±1 °C Easiest to use IR calibrator.
Three set-points—all reached quickly.
Enquiry

Metrology Wells

Model Range Accuracy Description/Features Email
9170 –45 °C to 140 °C
(–49 °F to 284 °F)
±0.1 °C Best-performing industrial heat sources (accuracy, stability, uniformity) in the world.
Immersion depth to 203 mm (8 in).
Optional ITS-90 reference input reads PRTs to ±0.006 °C.
Temperature range from –45 °C to 700 °C.
Enquiry
9171 –30 °C to 155 °C
(–22 °F to 311 °F)
±0.1 °C Enquiry
9172 35 °C to 425 °C
(95 °F to 797 °F)
±0.1 °C at 100 °C
±0.15 °C at 225 °C
±0.2 °C at 425 °C
Enquiry
9173 50 °C to 700 °C
(122 °F to 1292 °F)
±0.2 °C at 425 °C
±0.25 °C at 660 °C
Enquiry

Zero Point Dry-well

Model Range Accuracy Description/Features Email
9101 0 °C
32 °F
±0.05 °C Solid-state cooling. Replaces messy ice baths—easy to operate. Three wells, each 6 inches deep. Enquiry

Dual Block Dry-well

Model Range Accuracy Description/Features Email
9011
Hot Block
50 °C to 670 °C
122 °F to 1238 °F
±0.15 °C at 100 °C
±0.65 °C at 600 °C
Combined ranges from –30 °C to 670 °C. 1 unit – 2 blocks.  Two independent temperature controllers (hot and cold side). Stability: ±0.01 °C.  Multi-hole inserts hold up to 8 probes at once. Enquiry
Cold Block –30 °C to 140 °C
–22 °F to 284 °F
±0.25 °C (insert wells)
±0.65 °c (fixed wells)
Enquiry

Portable Lab Dry-wells

Model Range Accuracy Description/Features Email
9007 –40 °C to 140 °C
–40 °F to 284 °F
±0.15 °C –40 °C with solid-state Peltier cooling.
Rugged truck-, plane-, and sea-worthy enclosure.
Enquiry

Furnaces

Model Range Accuracy Description/Features Email
9150 Thermocouple Furnace 150 °C to 1200 °C
302 °F to 2192 °F
±0.5 °C Benchtop thermocouple furnace.
Interchangeable insert sleeves.
Fast heating and cooling.
Enquiry
9112B Calibration Furnace 300 °C to 1100 °C
572 °F to 2012 °F
±0.1 °C Standard block fits five probes.
Accommodates long probes.
Gradients less than ±0.3 °C at 1000 °C.
Enquiry

Fluke-Hart Scientific Temperature Calibration

Fluke Metrology Well +50~660°C
Fluke Metrology Well +50~660°C

Fluke 9144 Field Metrology Wells

  • Temperature range between 50°C and 660°C
    Lightweight, portable, and fast
    Cool to 50°C in 15 minutes and heat to 660°C in 15 minutes
    Metrology performance in accuracy, stability, uniformity, and loading
    LCD display continuously shows many useful operating parameters including the block temperature, the current set-point, block stability, and heating and cooling status.
    Multiple sized sensor holes to accept a wide range of temperature sensor diameters
  • 9144-P Additional Features

    Combines the drywell heat source with a built-in readout eliminating the need to take two instruments to the field.
    Built-in two-channel readout for PRT, RTD, thermocouple and 4-20 mA current with 24V loop power for transmitter loop, comparison calibration, or a simple check of a thermocouple sensor.
    On-board automation and results documentatio

Email Enquiry