RF Test Equipment, Spectrum Analyser, Signal Generator, Power Meter, EMC Test Equipment, TV Test Equipment, Oscilloscopes, Power Analyser, Kyoritsu, Hameg, Rohde & Schwarz, Yokogawa, Calibration, Environmental Testers, Multimeters, Insulation Testers, Thermal imaging, Network Analysers, Protocol Testers, Broadcast Test Equipment, MPEG Analysers, Promax, Thickness Testers, Concrete Testers, Radio Testers, Comms Analysers, Modulators, Demodulators, Fluke, Test Equipment, Test & measurement in Queensland, LCR Meters, Handheld Test Equipment, Power Supplies, Data Aquisition, Data Loggers, Meggers, PAT Testers, Portable Appliance Testers, Clamp meters, Function Generators, Calibrators, Temperature Measurement, Vibration Meters, Surface Roughness Testers, Recorders, Amprobe, Home About Us Search Links Products Suppliers Contact Us
Search for Product

Thermometer Probes

PRTs, Thermistors, Thermocouples and Liquid in Glass Thermometers

NEW! Secondary Standard PRT with Calibration Options

      Email
5608-9-X –200 to 500 °C 9 in x 1/8 in Enquiry
5608-12-X –200 to 500 °C 12 in x 1/8 in Enquiry
5609-12-X –200 to 670 °C 12 in x 1/4 in Enquiry
5609-15-X –200 to 670 °C 15 in x 1/4 in Enquiry
5609-20-X –200 to 670 °C 20 in x 1/4 in Enquiry
5609-300-X –200 to 670 °C 300 mm x 6 mm Enquiry
5609-400-X –200 to 670 °C 400 mm x 6 mm Enquiry
5609-500-X –200 to 670 °C 500 mm x 6 mm Enquiry

PRTs

Secondary Standards PRTs

Model Range Size Basic Accuracy  Email
5626 –200 °C to 661 °C 305 or 381 x 6.35 mm
(12 or 15 x 0.25 in)
±0.007 °C at 0 °C Enquiry
5628 –200 °C to 661 °C 305 or 381 x 6.35 mm
(12 or 15 x 0.25 in)
±0.006 °C at 0 °C Enquiry

NEW! Secondary Reference PRTs

Model Range Size Basic Accuracy   Email
5615-6 –200 to 300 °C 4.76 mm x 152 mm
(0.188 x 6.0 in)
  Enquiry
5615-9 –200 °C to 420 °C 4.76 mm x 229 mm
(0.188 x 9.0 in)
  Enquiry
5615-12 –200 °C to 420 °C
6.35 mm x 305 mm
(0.250 x 12.0 in)
  Enquiry

Precision Industrial PRTs

Model Range Size Basic Accuracy   Email
5627A-6 –200 °C to 300 °C 152 x 4.7 mm
(6 x 0.187 in)
±0.05 °C at 0 °C Enquiry
5627A-9 –200 °C to 300 °C 229 x 4.7 mm
(9 x 0.187 in)
±0.05 °C at 0 °C Enquiry
5627A-12 –200 °C to 420 °C 305 x 6.35 mm
(12 x 0.25 in)
±0.05 °C at 0 °C Enquiry

Fast Response PRTs

Model Range Size Basic Accuracy   Email
5622-05 –200 °C to 350 °C 100 x 0.5 mm ±0.04 °C at 0 °C Enquiry
5622-10 –200 °C to 350 °C 100 x 1.0 mm ±0.04 °C at 0 °C Enquiry
5622-16 –200 °C to 350 °C 200 x 1.6 mm ±0.04 °C at 0 °C Enquiry
5622-32 –200 °C to 350 °C 200 x 3.2 mm ±0.04 °C at 0 °C Enquiry

Small Diameter Industrial PRTs

Model Range Size Basic Accuracy   Email
5618B-6 –200 °C to 300 °C 152 x 3.2 mm
(6 x 0.125 in)
±0.05 °C Enquiry
5618B-9 –200 °C to 300 °C 229 x 3.2 mm
(9 x 0.125 in)
±0.05 °C Enquiry
5618B-12 –200 °C to 300 °C 305 x 3.2 mm
(12 x 0.125 in)
±0.05 °C Enquiry

Special Application PRTs

Model Range Size Basic Accuracy   Email
5623B Freezer Probe –200 °C to 156 °C 152 x 6.35 mm
(6 x 0.25 in)
±0.05 °C Enquiry
5624 High Temperature PRT 0 °C to 1000 °C 508 x 6.35 mm
(20 x 0l25 in)
±0.055 °C Enquiry

Thermistors

Thermistor Standards

Model Range Size Basic Accuracy   Email
5640 0 °C to 60 °C 229 x 6.35 mm
(9 x 0.25 in)
±0.0015 °C Enquiry
5641 0 °C to 60 °C 114 x 3.2 mm
(4.5 x 0.125 in)
±0.001 °C Enquiry
5642 0 °C to 60 °C 229 x 3.2 mm
(9 x 0.125 in)
±0.001 °C Enquiry
5643 0 °C to 100 °C 114 x 3.2 mm
(4.5 x 0.125 in)
±0.0025 °C Enquiry
5644 0 °C to 100 °C 229 x 3.2 mm
(9 x 0.125 in)
±0.0025 °C Enquiry

Secondary Thermistor Probes

Model Range Size Basic Accuracy   Email
5610 0 °C to 100 °C 152 or 229 x 3.2 mm
(6 or 9 x 0.125 in)
±0.01 °C
Enquiry
5611A 0 °C to 100 °C 1.5 mm
(0.06 in) tip dia.
±0.01 °C
Enquiry
5611T 0 °C to 100 °C 28 x 3 mm
(1.1 x 0.12 in)
±0.01 °C
Enquiry
5665 0 °C to 100 °C 76 x 3.2 mm
(3 x 0.125 in)
±0.01 °C
Enquiry

Thermocouples

Type R and S Thermocouple Standards

Model Range Size Basic Accuracy   Email
5649/5650-20 0 °C to 1450 °C 508 x 6.35 mm
(20 x 0.25 in)
±0.7 °C at 1100 °C Enquiry
5649/5650-20C 0 °C to 1450 °C 508 x 6.35 mm
(20 x 0.25 in)
±0.7 °C at 1100 °C Enquiry
5649/5650-25 0 °C to 1450 °C 635 x 6.35 mm
(20 x 0.25 in)
±0.7 °C at 1100 °C Enquiry
5649/5650-25C 0 °C to 1450 °C 635 x 6.35 mm
(20 x 0.25 in)
±0.7 °C at 1100 °C Enquiry

Other

Type R and S Thermocouple Standards

Model Range Size Basic Accuracy   Email
Glass Thermometers –38 °C to 405 °C
–36 °F to 761 °F
381 mm (15 in) length 0.1 °C Divisions
0.2 °F Divisions
Enquiry
    “Basic Accuracy” includes calibration uncertainty and short-term repeatability. It does not include
    long-term drift.

 



Currently no items in this category.